Fire / ignition
Extension cord
[Translated from Japanese] NITE SAFE-Lite accident A202400256 (2024/06/09). Product: Yamato Denki T5317E11. Incident: at a store, the product electrical products to connected and when, 、because an unusual noise occurredupon checking、the product burn damage firehad occurred。 (accident location: Kanagawa Prefecture) Investigation note: As a result of the investigation, ○the product had been doing so, but abnormalities such as burn damage and deformation to the resin outer shell were not observed. ○Power plug plug blade one side deformed had been doing so, but power plug resin outer shell burn damagewas not observed. ○Dielectric breakdown between different poles was not observed at each outlet, and power plug energized / powered-on state abnormality was not observed at each outlet. ○The product Inside the tap Parts for countermeasures against lightning surges, etc. Some varistors burn damage and element through holes were observed. ●The product, the varistor short circuit inside the tap and it is presumed to have ignited, but the detailed circumstances before the accident occurred unknownbecause of / due to, including whether it was product-related, the accident cause could not be identified. Cause class: n/a. Harm reported: 11.fire.
UnverifiedEvidence ★★★★☆View report detailsHide report details
Fire / ignition
Extension cord
Months until failure
Not stated
Repair cost
Not stated
Repaired
Not stated
Manufacturer warranty
Not stated
Extended warranty
Not stated
Support helpful
Not stated
Would recommend
Not stated
AI extraction confidence
86%
Verification status
Unverified
Evidence quality
★★★★☆ (4/5)