Product

Seiko RC01

Category

Home & Garden

Failure type

Fire / ignition

Accident narrative

[Translated from Japanese] NITE SAFE-Lite accident 2000-0792 (2000/09/18). Product: Charger RC01 for Seiko ES1910. Incident: While charging the shaver by plugging it into the charger, smoke was emitted from the charger and it caught fire, scorching the vanity unit and leaving soot stains on the wall, ceiling, and washing machine. Investigation note: There was an insulation defect in the winding section of the oscillation transformer inside the charger, so there was a partial short circuit between the windings, causing an overcurrent to flow. Due to the heat generated when the fuse resistor of the circuit melted/blew, the potting compound/filler around the fuse resistor carbonized, forming a bypass circuit. Then, current continued to flow through that area, causing overheating and ignition. Cause class: A1. Harm reported: 4. Property damage (extended). Reported use period: unknown.

This is an official accident-information record from NITE SAFE-Lite (事故情報), not a recall notice. Cause determinations may be under investigation or marked as not product-attributable in the original record.

Official year/case number: 2000-0792. Search this ID on SAFE-Lite to open the original Japanese accident record.