Product
Panasonic CW-C18AS
Category
Home & Garden
Failure type
Fire / ignition
Accident narrative
[Translated from Japanese] NITE SAFE-Lite accident 2000-0825 (2000/08/29). Product: Panasonic CW-C18AS. Incident: A neighbor discovered ignition and smoke emission from a window-type room air conditioner installed in the north-facing window on the second floor of the office. The neighbor called 119 and also informed the site office, and site office staff extinguished the fire with a fire extinguisher. Investigation note: It is presumed that rainwater that entered through gaps in the main unit during a severe wind and rainstorm, and condensation that formed on the underside of the drip tray due to harsh operating conditions, penetrated into the internal electrical components (relays) of the control circuit board. As a result, the insulation properties of the relays deteriorated, leading to ignition within the relays and subsequent ignition of the insulated lead wires and resin structures surrounding the relays. Cause class: A1. Harm reported: 5. Product damage. Reported use period: unknown.
Official year/case number: 2000-0825. Search this ID on SAFE-Lite to open the original Japanese accident record.