Product
Seiko RC01
Category
Home & Garden
Failure type
Fire / ignition
Accident narrative
[Translated from Japanese] NITE SAFE-Lite accident 2002-0733 (2002/07/15). Product: Charger RC01 for Seiko ES1910. Incident: Smoke was emitted from the charger and it caught fire while a shaver was being charged on top of the washing machine, scorching the lid of the washing machine and causing soot stains on the clothes in the drum. Investigation note: There was an insulation defect in the winding section of the oscillation transformer inside the charger, so there was a partial short circuit between the windings, causing an overcurrent to flow. Due to the heat generated when the fuse resistor of the circuit melted/blew, the potting compound/filler around the fuse resistor carbonized, forming a bypass circuit. Then, current continued to flow through that area, causing overheating and ignition. Cause class: A1. Harm reported: 4. Property damage (extended). Reported use period: Approximately 2 years and 3 months.
Official year/case number: 2002-0733. Search this ID on SAFE-Lite to open the original Japanese accident record.