Verified government source

NITE accident 2003-0601

Product accident information from Japan's National Institute of Technology and Evaluation (NITE) SAFE-Lite database. Narratives are translated to English for display; verify the original Japanese record on SAFE-Lite.

Product

Seiko RC01

Category

Home & Garden

Failure type

Fire / ignition

Accident narrative

[Translated from Japanese] NITE SAFE-Lite accident 2003-0601 (2003/05/10). Product: Charger RC01 for Seiko ES1910. Incident: Storeroom TV stand top shaver while charging, charger from smoke emission, ignited. poured water and extinguished the fire, part of the TV stand scorched, and the room became soot-stained. Investigation note: There was an insulation defect in the winding section of the oscillation transformer inside the charger, so there was a partial short circuit between the windings, causing an overcurrent to flow. Due to the heat generated when the fuse resistor of the circuit melted/blew, the potting compound/filler around the fuse resistor carbonized, forming a bypass circuit. Then, current continued to flow through that area, causing overheating and ignition. Cause class: A1. Harm reported: 4. Property damage (extended). Reported use period: unknown.

This is an official accident-information record from NITE SAFE-Lite (事故情報), not a recall notice. Cause determinations may be under investigation or marked as not product-attributable in the original record.

Official year/case number: 2003-0601. Search this ID on SAFE-Lite to open the original Japanese accident record.