Product
Toshiba IL-1013
Category
Home & Garden
Failure type
Fire / ignition
Accident narrative
[Translated from Japanese] NITE SAFE-Lite accident 2004-0563 (2004/06/21). Product: Toshiba IL-1013. Incident: On the second floor, a ceiling-mounted, hanging incandescent light fixture caused ignition, poured water and extinguished the fire, resulting in a trip on the stairs and a bruise. Investigation note: Cord insulation deterioration due to long-term use (about 37 years) Insulation deterioration due to long-term use (about 37 years) Occurred when replacing lamps, etc. Accidental downward load (accidental pulling, etc.) due to / by Cord Mechanical stress added, maximum stress Applied Cord holder Between sockets Between core wires Insulation deterioration progresses, slight discharge occurs and eventually short circuit / ignition is estimated. Cause class: C1. Harm reported: 3. Minor injury. Reported use period: about 37 years.
Official year/case number: 2004-0563. Search this ID on SAFE-Lite to open the original Japanese accident record.