Verified government source

NITE accident 2004-1318

Product accident information from Japan's National Institute of Technology and Evaluation (NITE) SAFE-Lite database. Narratives are translated to English for display; verify the original Japanese record on SAFE-Lite.

Product

Toshiba RAS-406LDR

Category

Home & Garden

Failure type

Fire / ignition

Accident narrative

[Translated from Japanese] NITE SAFE-Lite accident 2004-1318 (2003/05/31). Product: Toshiba RAS-406LDR. Incident: While the air conditioner was in use, a "pop" sound came from the indoor unit, followed by smoke emission and ignition. I unplugged the power plug from the outlet, but I saw flames, so I poured water on it and extinguished the fire, but it soiled/contaminated the surrounding area. Investigation note: Burn damage was observed in the power connector of the fan motor inside the indoor unit of the air conditioner, which appears to be due to tracking. Since the user had requested a cleaning service to perform cleaning with the electrical components installed, it is presumed that air conditioner cleaning solution or similar conductive electrolytic substances adhered to and remained on the connector, and the condensation that occurred inside the indoor unit triggered the tracking phenomenon. Cause class: B1. Harm reported: 4. Property damage (extended). Reported use period: Approximately 3 years and 6 months.

This is an official accident-information record from NITE SAFE-Lite (事故情報), not a recall notice. Cause determinations may be under investigation or marked as not product-attributable in the original record.

Official year/case number: 2004-1318. Search this ID on SAFE-Lite to open the original Japanese accident record.