Verified government source

NITE accident 2004-2452

Product accident information from Japan's National Institute of Technology and Evaluation (NITE) SAFE-Lite database. Narratives are translated to English for display; verify the original Japanese record on SAFE-Lite.

Product

Daikin AR2205X

Category

Home & Garden

Failure type

Fire / ignition

Accident narrative

[Translated from Japanese] NITE SAFE-Lite accident 2004-2452 (2005/02/11). Product: Daikin AR2205X. Incident: I requested an inspection because I heard a "crackling" sound from the outdoor unit of the air conditioner. During the inspection by the management company, they removed the top panel of the outdoor unit and looked into the electrical components, causing ignition and resulting in burns to the face. Investigation note: At the soldered connections between the printed circuit board and the diode bridge, there were instances of insufficient solder. Due to the difference in thermal expansion between the printed circuit board and the electrical equipment box, repeated stress was applied to the soldered joints, causing solder cracks. Consequently, reverse voltage was applied to the electrolytic capacitor, leading to damage to the capacitor itself and leakage of electrolyte. This resulted in sparking due to ignition, and it is presumed that the electrical equipment was burned or fire-damaged. Cause class: A2. Harm reported: 3. Minor injury. Reported use period: About 10 years.

This is an official accident-information record from NITE SAFE-Lite (事故情報), not a recall notice. Cause determinations may be under investigation or marked as not product-attributable in the original record.

Official year/case number: 2004-2452. Search this ID on SAFE-Lite to open the original Japanese accident record.