Accident narrative
[Translated from Japanese] NITE SAFE-Lite accident 2006-0968 (2006/07/19). Product: Mitsubishi VL-1600Z-1. Incident: I heard a "crackling" sound from the ventilation fan, so I opened the panel to check, and smoke emission ignited. Investigation note: This is a ventilation fan that simultaneously intakes and exhausts air. It was used for a long period (approximately 16 years) in an environment where it exhausted indoor air during cooling and intook hot and humid outside air. It is presumed that hot and humid outside air entered and condensed near the terminal block inside the equipment, causing insulation breakdown at the power supply terminal, leading to tracking, smoke emission, and ignition. Cause class: C1. Harm reported: 4. Property damage (extended). Reported use period: Around April 2016.
Official year/case number: 2006-0968. Search this ID on SAFE-Lite to open the original Japanese accident record.