Verified government source

NITE accident A201000190

Product accident information from Japan's National Institute of Technology and Evaluation (NITE) SAFE-Lite database. Narratives are translated to English for display; verify the original Japanese record on SAFE-Lite.

Product

Toshiba PS18070C4418

Category

Electronics

Failure type

Fire / ignition

Accident narrative

[Translated from Japanese] NITE SAFE-Lite accident A201000190 (2010/05/22). Product: Toshiba PS18070C4418. Incident: The AC adapter was connected to the product and during use, I left the area. An unusual noise was heard, and upon checking, a fire broke out from the product, causing the product and its surroundings to be burned/fire-damaged. (Accident location: Hiroshima Prefecture) Investigation note: The cause of the incident is considered to be that a short circuit occurred inside the battery pack of the product during manufacturing, potentially causing ignition, leading to a fire originating from inside the product. However, the burn damage to the electrode foil inside the cell was significant, and the exact cause could not be determined. Cause class: n/a. Harm reported: 11.fire.

This is an official accident-information record from NITE SAFE-Lite (事故情報), not a recall notice. Cause determinations may be under investigation or marked as not product-attributable in the original record.

Official year/case number: A201000190. Search this ID on SAFE-Lite to open the original Japanese accident record.