Verified government source

NITE accident A201000697

Product accident information from Japan's National Institute of Technology and Evaluation (NITE) SAFE-Lite database. Narratives are translated to English for display; verify the original Japanese record on SAFE-Lite.

Product

Torii Electric K-A-2

Category

Home & Garden

Failure type

Fire / ignition

Accident narrative

[Translated from Japanese] NITE SAFE-Lite accident A201000697 (2010/10/31). Product: Torii Electric K-A 2. Incident: The product was installed in a lighting fixture, and an incandescent light bulb was fitted. During use, the circuit breaker tripped. When the circuit breaker was reset, sparks occurred, igniting flammable materials and causing a fire. The product and its surroundings were burned/fire-damaged. (Same accident as A201000668) (Accident location: Tokyo) Investigation note: The cause of the accident is considered to be that, although the product was designed for use with 10-15W fluorescent lamps, there was no indication on the product itself or in the instruction manual prohibiting the use of incandescent bulbs. As a result, the product was mistakenly used with a higher-rated incandescent bulb (60W), causing the plastic parts of the product to melt and the insulation to deteriorate. This led to the product being damaged during bulb replacement, resulting in a fire. Cause class: n/a. Harm reported: 11.fire.

This is an official accident-information record from NITE SAFE-Lite (事故情報), not a recall notice. Cause determinations may be under investigation or marked as not product-attributable in the original record.

Official year/case number: A201000697. Search this ID on SAFE-Lite to open the original Japanese accident record.