Product
Torii Electric K-A-2
Category
Home & Garden
Failure type
Fire / ignition
Accident narrative
[Translated from Japanese] NITE SAFE-Lite accident A201000697 (2010/10/31). Product: Torii Electric K-A 2. Incident: The product was installed in a lighting fixture, and an incandescent light bulb was fitted. During use, the circuit breaker tripped. When the circuit breaker was reset, sparks occurred, igniting flammable materials and causing a fire. The product and its surroundings were burned/fire-damaged. (Same accident as A201000668) (Accident location: Tokyo) Investigation note: The cause of the accident is considered to be that, although the product was designed for use with 10-15W fluorescent lamps, there was no indication on the product itself or in the instruction manual prohibiting the use of incandescent bulbs. As a result, the product was mistakenly used with a higher-rated incandescent bulb (60W), causing the plastic parts of the product to melt and the insulation to deteriorate. This led to the product being damaged during bulb replacement, resulting in a fire. Cause class: n/a. Harm reported: 11.fire.
Official year/case number: A201000697. Search this ID on SAFE-Lite to open the original Japanese accident record.