Verified government source

NITE accident A201000948

Product accident information from Japan's National Institute of Technology and Evaluation (NITE) SAFE-Lite database. Narratives are translated to English for display; verify the original Japanese record on SAFE-Lite.

Product

Panasonic WH2723TWP

Category

Electronics

Failure type

Fire / ignition

Accident narrative

[Translated from Japanese] NITE SAFE-Lite accident A201000948 (2011/01/13). Product: Panasonic WH2723TWP. Incident: the product electric stove (oil heater) connected and during use, firebecause the alarm sounded, upon checking, the product burn damage firehad occurred. (accident location: Fukuoka prefecture) Investigation note: as a result of the investigation, the accident cause is long-term use (about 20 years) due to / by the product. In addition, the instruction manual for electric stoves states, ``Never use extension cord power strips, sockets, etc.'' and ``Power source: AC 100V (50/60Hz) 15A 125V, plug directly into wall outlet.'' Cause class: n/a. Harm reported: 11.fire.

This is an official accident-information record from NITE SAFE-Lite (事故情報), not a recall notice. Cause determinations may be under investigation or marked as not product-attributable in the original record.

Official year/case number: A201000948. Search this ID on SAFE-Lite to open the original Japanese accident record.