Product

Ohm Electric HS-T2002W

Category

Electronics

Failure type

Fire / ignition

Accident narrative

[Translated from Japanese] NITE SAFE-Lite accident A201100084 (2011/02/08). Product: Ohm Electric HS-T2002W. Incident: After connecting an electric carpet to the product and turning it on, an abnormality was noticed after a while. Upon checking, it was found that a fire had occurred, causing burn damage to the product and the surrounding area. (accident location: Aichi Prefecture) Investigation note: The cause of the accident is considered to be that the crimped connection between the cord core wire and the blade receptacle bracket inside the power strip of the product was defective due to a disconnection, causing heat generation. Additionally, a kotatsu blanket was covering the power strip, leading to a rise in temperature inside the cord protector. This caused the insulation to melt, resulting in a short circuit and sparking in the cord core wire, ultimately leading to a fire. Cause class: n/a. Harm reported: 11.fire.