Verified government source

NITE accident A201300292

Product accident information from Japan's National Institute of Technology and Evaluation (NITE) SAFE-Lite database. Narratives are translated to English for display; verify the original Japanese record on SAFE-Lite.

Product

Hitachi RP7B620WH

Category

Home & Garden

Failure type

Fire / ignition

Accident narrative

[Translated from Japanese] NITE SAFE-Lite accident A201300292 (2013/07/06). Product: Hitachi RP7B620WH. Incident: During use of the product, an unusual noise was heard. Upon checking, smoke was emitted from the product, and a fire had occurred, causing burn damage to the internal components of the product. (accident location: Tokyo) Investigation note: The cause of the accident is considered to be that, due to the long-term use of the product (approximately 28 years), the primary winding of the ballast for the 32W fluorescent lamp deteriorated in insulation, resulting in a layer short circuit and abnormal overheating, leading to a fire. Cause class: n/a. Harm reported: 11.fire.

This is an official accident-information record from NITE SAFE-Lite (事故情報), not a recall notice. Cause determinations may be under investigation or marked as not product-attributable in the original record.

Official year/case number: A201300292. Search this ID on SAFE-Lite to open the original Japanese accident record.