Verified government source

NITE accident A201300887

Product accident information from Japan's National Institute of Technology and Evaluation (NITE) SAFE-Lite database. Narratives are translated to English for display; verify the original Japanese record on SAFE-Lite.

Product

NEC PA-WR8170N-ST

Category

Home & Garden

Failure type

Fire / ignition

Accident narrative

[Translated from Japanese] NITE SAFE-Lite accident A201300887 (2014/03/03). Product: NEC AccessTechnica PA-WR8170N-ST. Incident: Multiple computer peripherals were connected to the product, and during use, a fire occurred that caused burn damage to the product and the surrounding area. (Same accident as A201300888 and A201300889) (Accident location: Chiba Prefecture) Investigation note: The investigation revealed that the AC adapter unit of ○the product was almost completely burned, leaving only a part of the circuit board, and most of the electrical components, such as the transformer and capacitors, could not be identified. ○ The insulation of the AC cord and DC cord of the AC adapter was burned away, but no signs of melting or other fire damage were observed on the core wires of the cords. Furthermore, no evidence of fire originating from the AC plug or DC plug was observed. ○ No burn damage was observed on the resin case of the product itself, and there were no signs of fire originating from inside. ● Since the product has significant burn damage to the AC adapter itself and there are parts that cannot be identified, it was not possible to determine the cause of the incident, including whether it was due to the product or not. Cause class: n/a. Harm reported: 11.fire.

This is an official accident-information record from NITE SAFE-Lite (事故情報), not a recall notice. Cause determinations may be under investigation or marked as not product-attributable in the original record.

Official year/case number: A201300887. Search this ID on SAFE-Lite to open the original Japanese accident record.