Product
Yamato Denki T2009
Category
Electronics
Failure type
Fire / ignition
Accident narrative
[Translated from Japanese] NITE SAFE-Lite accident A202100574 (2021/09/07). Product: Yamato Denki T2009. Incident: the product electrical products to connected and during use、unusual odoroccurred, so upon checking、the productandthe surrounding area burn damage firehad occurred。 (A202100521same incident as )(accident location: Saitama Prefecture) Investigation note: as a result of the investigation, ○at the time of the accident, the product, power plug connected and during use was. ○The product power plug resin outer shell was severe burn damage, wire breakage at the base of the cord protector, melting marks was observed at the breakage point, burn damage was not observed at the tap. ○Power plug plug blades One side Caulked part melted / blewhad been doing so, but , melted / blew Plug blade Blade holder Contact part Spark trace was not observed. ○A bend in the core wire was observed near the power cord disconnection. ○the product power plugwas connectedoutlet no ignition traces were found。 ●The product had a half-broken wire due to bending in the cord protector from abnormal overheating when energized, it is presumed this led to ignition, but the product burn damage was severe, detailed prior usage conditions were unknownbecause of / due to, including whether it was product-related, the accident cause could not be identified. Cause class: n/a. Harm reported: 11.fire.
Official year/case number: A202100574. Search this ID on SAFE-Lite to open the original Japanese accident record.