Verified government source

NITE accident A202300573

Product accident information from Japan's National Institute of Technology and Evaluation (NITE) SAFE-Lite database. Narratives are translated to English for display; verify the original Japanese record on SAFE-Lite.

Product

Makita DC18RF

Category

Home & Garden

Failure type

Fire / ignition

Accident narrative

[Translated from Japanese] NITE SAFE-Lite accident A202300573 (2023/07/21). Product: Makita DC18RF. Incident: While charging the battery with the product at the facility, an unusual noise was heard. Upon checking, it was found that a fire had occurred, causing burn damage to the product and the surrounding area. One person sustained serious injuries, and seven others suffered minor injuries. (accident location: Kanagawa Prefecture) Investigation note: The investigation revealed that at the time of the incident, the product, products of the same model, and two batteries for electric vacuum cleaners (manufacturer unknown) were present at the scene. It was reported that either the product or a product of the same model was being used to charge a battery for an electric vacuum cleaner. ○ The product and products of the same model showed significant burn damage. Resin parts such as the outer casing were burned away, and only the circuit board could be identified. However, electrical components such as the power cord and cooling fan could not be identified. ○ On both the product and the same model, all circuit boards showed significant burn damage, components on the circuit boards had fallen off, and parts of the copper foil pattern were peeling off. ○ Twenty cylindrical lithium-ion battery cells, including one from an electric-assist bicycle battery, were recovered from the scene of the accident, but all of them were significantly burned and it was not possible to determine whether they were from the battery that was being charged by the product. ● The product has significant burn damage, and there are parts that cannot be identified. Therefore, it was not possible to determine the cause of the incident, including whether it was due to the product or not. Cause class: n/a. Harm reported: 2. Serious injury:11.fire.

This is an official accident-information record from NITE SAFE-Lite (事故情報), not a recall notice. Cause determinations may be under investigation or marked as not product-attributable in the original record.

Official year/case number: A202300573. Search this ID on SAFE-Lite to open the original Japanese accident record.