Verified government source

NITE accident A202301137

Product accident information from Japan's National Institute of Technology and Evaluation (NITE) SAFE-Lite database. Narratives are translated to English for display; verify the original Japanese record on SAFE-Lite.

Product

Anker PowerCore (A1246012)

Category

Charger & Power Accessory

Failure type

Fire / ignition

Accident narrative

[Translated from Japanese] NITE SAFE-Lite accident A202301137 (2024/02/11). Product: Anker A1246012. Incident: the product while charging、unusual odorandbecause an unusual noise occurredupon checking、the productandthe surrounding area burn damage firehad occurred。 (accident location: Osaka Prefecture) Investigation note: As a result of the investigation, the product was severely burnt and the circuit board, battery, outer resin, etc. were in a state of separation. ○Built-in lithium-ion battery cell exterior has been burnt and expanded. Electrode body copper foil has been exposed and electrode body has been severely burn damaged. ○Control circuit board and protective circuit board were misaligned, many parts on the circuit board had been doing so, but burnout of the base material was not observed. ○The product connected and ACadapter output voltage abnormality was not observed. ●The product, the built-in lithium-ion battery cell abnormal overheating and it is presumed to have ignited, but detailed prior usage conditions were unknown, including whether it was product-related, the cause of the accident could not be determined. Cause class: n/a. Harm reported: 11.fire.

This is an official accident-information record from NITE SAFE-Lite (事故情報), not a recall notice. Cause determinations may be under investigation or marked as not product-attributable in the original record.

Official year/case number: A202301137. Search this ID on SAFE-Lite to open the original Japanese accident record.