Product
Ohm Electric HKD-31T
Category
Electronics
Failure type
Fire / ignition
Accident narrative
[Translated from Japanese] NITE SAFE-Lite accident A202401188 (2025/02/19). Product: Ohm Electric HKD-31T. Incident: When another extension cord was connected to the product and an electrical appliance was being used, an unusual noise and smoke emission were noticed. Upon checking, it was found that the product had suffered burn damage, and a fire had occurred, causing soiling/contamination of the surrounding area. (accident location: Aichi Prefecture) Investigation note: The investigation revealed that the area around the power cord socket on the resin casing of the 3-socket power strip had suffered burn damage, and the socket was blocked. However, no burn damage was observed on the power cord or the power plug. ○ Inside the power strip, the power cord was disconnected at the base of the cord protector, and melting marks were observed on the disconnected part, but no signs of fire, such as melting marks, were observed on the blade holder bracket. ○ The area around the socket was burned / fire-damaged. The inner surface of the outer casing was slightly thermally deformed, but no burn damage was observed. ○ Although no signs of fire, such as melting marks, were observed in the crimped part of the power cord of the blade holder bracket, when the resistance value between the core wire and the blade holder bracket was measured, the values for both poles were not stable. ○ The product had a third-party extension cord connected to a three-outlet power strip. The third-party extension cord was connected to a power strip to which an air conditioner (maximum power consumption: 1290W) and another third-party extension cord were connected. However, the air conditioner was not in use at the time of the incident. ● The product Cause class: n/a. Harm reported: 11.fire.
Official year/case number: A202401188. Search this ID on SAFE-Lite to open the original Japanese accident record.