Product
Daikin F36GTPS
Category
Home & Garden
Failure type
Fire / ignition
Accident narrative
[Translated from Japanese] NITE SAFE-Lite accident A202500037 (2025/03/30). Product: Daikin F36GTPS. Incident: When the operation of the product was stopped, a fire occurred, causing smoke emission from the product. (accident location: Tokyo) Investigation note: It is considered that a defect in the manufacturing process of the product's fan motor due to/by an electronic component (chip capacitor) built into the fan motor short-circuiting (short-circuit failure), causing an excessive current to flow through the electrical circuit, resulting in the fan motor overheating and igniting, leading to a fire. Cause class: n/a. Harm reported: 11.fire.
Official year/case number: A202500037. Search this ID on SAFE-Lite to open the original Japanese accident record.