Verified government source

SaferProducts incident

Official U.S. Consumer Product Safety Commission consumer incident report from the SaferProducts.gov public database. Use the verification links below to confirm the record on SaferProducts.gov or via the public database export.

Product

Amana ARB1917CC

Category

Kitchen Appliance

Report number

20110715-1509A-2147477188

Ownership age

About 88 months to failure (from purchase date when reported)

Failure type

Fire / ignition

Incident narrative

SaferProducts.gov consumer incident report 20110715-1509A-2147477188. Severity: Incident, No Injury. Product: Amana ARB1917CC (Amana bottom freezer refrigerator). Incident: Odor of burning electrical plastic in kitchen. Found to be coming from Amana refrigerator. Unit was then unplugged for safety. Appliance repair technician was called next day (7/15/11) and found the compressor starter relay had burnt. Visible charring and melting inside the relay which I have saved if needed for inspection. Checked with Amana but they report my model (ARB1917CC) is not listed in their recall of refrigerators where this same part has caught fire. Identification number stampings on failed relay are 5SPD4T419PFM 21 R03R 419PFBYY -77 GAM3L

This is a consumer incident report published on SaferProducts.gov. CPSC does not guarantee the accuracy of information submitted by people outside of CPSC. It is not automatically an official recall or manufacturer admission.

Official report number: 20110715-1509A-2147477188. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.