Product
Kidde Model 30CUA10
Category
Smart Home Device
Report number
20121111-B8A84-2147462060
Ownership age
About 0 months to failure (from purchase date when reported)
Failure type
Fire / ignition
Incident narrative
SaferProducts.gov consumer incident report 20121111-B8A84-2147462060. Severity: Incident, No Injury. Matched catalog product: Kidde Model 30CUA10. Source model text: KN-COB-B-LPM. Incident: 3 day old Carbon Monoxide detector failed to sound alarm with high CO levels. (Separate secondary alarm sounded. Fire department notified). Fire department found high CO levels, verified suspect CO detector was inoperative. Unit self-tests okay, but does not actuate during actual event. Unit Details: Kidde Single Station Carbon Monoxide alarm (Issue No 4477) Model KN-COB-B-LPM, Assemblt number 9CO5-LP. Date of Manufacture 2012, June, 25.
Official report number: 20121111-B8A84-2147462060. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.