Product

Bosch Dishwasher SHE43F16UC-60

Category

Kitchen Appliance

Report number

20130819-9DDE4-2147452885

Ownership age

About 37 months to failure (from purchase date when reported)

Failure type

Fire / ignition

Incident narrative

SaferProducts.gov consumer incident report 20130819-9DDE4-2147452885. Severity: Incident, No Injury. Product: Bosch SHE43F16UC/60 (Built-In Dishwasher). Incident: On July 25, 2013, our Bosch Dishwasher model SHE43F16Uc/60, Serial # 900500974 caught fire where the wiring harness attaches to the terminal junction block. The fire burned the terminal junction block, wiring harness and extended to the electric supply wiring through our floor. We were very fortunate that we were home and awake when this occured as the burning wire smell alerted us to the fire. Upon investigation by an electrician and a factory service technician, both concurred that the fire originated where the wiring harness attaches to the terminal block due to a loose connection that caused the wires to arc. The factory repair technician indicated that he has seen this failure in other Bosch dishwashers.While Bosch contends that the fire was a result of an installation issue, the dishwasher was installed in July, 2011 without any incident until July 25, 2013. Also be advised that the terminal block-wire harness connection was factory installed and not to be adjusted by the installer. In fact the installation guidelines make no reference at all to the terminal block-wiring harness connection. The instructions are limited to the instalation of the ground, neutral and hot wire to the terminal screws.

This is a consumer incident report published on SaferProducts.gov. CPSC does not guarantee the accuracy of information submitted by people outside of CPSC. It is not automatically an official recall or manufacturer admission.

Official report number: 20130819-9DDE4-2147452885. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.