Verified government source

SaferProducts incident

Official U.S. Consumer Product Safety Commission consumer incident report from the SaferProducts.gov public database. Use the verification links below to confirm the record on SaferProducts.gov or via the public database export.

Product

Rheem 22V40FN

Category

Kitchen Appliance

Report number

20131106-C2AF3-2147450178

Ownership age

About 0 months to failure (from purchase date when reported)

Failure type

Fire / ignition

Incident narrative

SaferProducts.gov consumer incident report 20131106-C2AF3-2147450178. Severity: Unspecified. Product: Rheem 22V40FN (Rheem Hot Water Tank - Gas Type Model Number: 22V40FN Serial Number: rhunm171212666). Incident: Please read below email thread: -----Original Message----- From: [REDACTED] Sent: Wednesday, November 06, 2013 08:04 To: 'TechAnalyst@rheem.com' Subject: FW: Rheem Consumer Website - Water Heating - Customer Service Dear Rheem, I contacted you in March for warranty service on a gas hot water tank that was less then a year old. See the message after this one below for the original details. The plumbing company that provided the warranty service did a great job. However, the serviceman and I concluded that it was entirely possible that the Rheem Hot Water Tank has a serious design flaw. Let me explain. The unit had a failure of the thermostat. However, after changing the thermostat the secondary problem of the burner not igniting properly did not go away even though the unit was now regulating the water temperature correctly. When the thermostat tripped the gas valve to open and ignite the burner the unit did not ignite in a timely manner. What happened is that much more gas than normal had to accumulate before the pilot ignited the gas. Basically, it created a small contained explosion inside the unit. You could hear it and sometimes see the entire unit shake. The serviceman ordered a new burner unit. It arrived and he installed it. The same thing happened. He pulled it out and inspected the floor of the unit and all the air paths. There was a MINOR and FINE amount of dust clinging to the small square (about 2x2 inch) section of air holes in the bottom of the unit. The holes were NOT BLOCKED, just some dust around the aperture of the holes. He took a powerful shop vacuum and

This is a consumer incident report published on SaferProducts.gov. CPSC does not guarantee the accuracy of information submitted by people outside of CPSC. It is not automatically an official recall or manufacturer admission.

Official report number: 20131106-C2AF3-2147450178. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.