Verified government source

SaferProducts incident

Official U.S. Consumer Product Safety Commission consumer incident report from the SaferProducts.gov public database. Use the verification links below to confirm the record on SaferProducts.gov or via the public database export.

Product

Goodman GKS90904CX

Category

Home & Garden

Report number

20160121-DA1E8-2147424489

Ownership age

Not stated

Failure type

Leak

Incident narrative

SaferProducts.gov consumer incident report 20160121-DA1E8-2147424489. Severity: Incident, No Injury. Product: Goodman GKS90904CX (Residential Natural Gas Furnace). Incident: 2016.01.21.03.58 I am a mandated reporter as a Mechanical Process Engineer. I developed manufacturing processes for 30 years and must report safety concerns. We had (operative phrase) a Goodman forced air natural gas furnace in our home for two years. On a basement re-organization I noticed water around the base of the furnace. Thinking failed condensate (it was a 92% efficient unit so was a condensing furnace) I checked the evacuator pump which was working 100%. Against all CO warnings I pulled the burner cover to see condensate water misting out of the seal between the recuperation coil cover and burner box. CO is potentially present in the area so I shut down the furnace, pulled the unit apart to find a very likely robot laid EPDM gasket out of place for about 10" long and 3/8" out off location on the lower right end of the panel that was to be sealed. Heavy trails of rust showed that it had been leaking since day one, 2 years ago. Goodman resisted at first but finally relented in installing a new furnace (100% functional now) after I threatened them with CPSC. The where about's of the problematic furnace is unknown and Goodman is un-responsive as to if it is being Six Sigma checked for other units of this popular furnace are out there. That's criminal. Safety of others at this point is my concern I have photos, serial and model numbers as well as all communication. Dutifully reported, respectfully yours, The [REDACTED] , a family company [REDACTED] , [REDACTED] & 2 children under 6 (concerned on low level CO for 2 years) [REDACTED] [REDACTED] [REDACTED] home [REDACTED]

This is a consumer incident report published on SaferProducts.gov. CPSC does not guarantee the accuracy of information submitted by people outside of CPSC. It is not automatically an official recall or manufacturer admission.

Official report number: 20160121-DA1E8-2147424489. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.