Product
Frigidaire P-N 2020264A0160 (Unit too destroyed in fire to get model #)
Category
Home & Garden
Report number
20160523-1A11D-2147419365
Ownership age
About 80 months to failure (from purchase date when reported)
Failure type
Fire / ignition
Incident narrative
SaferProducts.gov consumer incident report 20160523-1A11D-2147419365. Severity: Incident, No Injury. Product: Frigidaire P/N 2020264A0160 (Unit too destroyed in fire to get model #) (Frigidaire 50 pint dehumidifier P/N 2020264A0160). Incident: We had a house fire May 21, 2016. Woke up to smoke at 4:45 AM and called 911, Fire Department came and put fire out. Fire Marshall determined cause of fire was Frigidaire Dehumidifier. The unit is so destroyed that I cannot pull the model number off of it, but we have the owners manual and the original receipt. The unit was purchased at Lowe's on Oct 7, 2009 as "50 PINT FRIG ESTAR DEHUM" with Lowe's stock number 288372. The owners manual does not show model number but shows P/N 2020264A0160. State Farm is our insurance company and the damages are being assessed. Major smoke and soot damage. Have already received an estimate from an electrician to repair, replace affected house wiring. Air Conditioning people to make estimation for damage to Daikon unit. ServPro still working on restoring/cleaning house to normal.
Official report number: 20160523-1A11D-2147419365. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.