Verified government source

SaferProducts incident

Official U.S. Consumer Product Safety Commission consumer incident report from the SaferProducts.gov public database. Use the verification links below to confirm the record on SaferProducts.gov or via the public database export.

Product

Stihl MS460

Category

Lawn Equipment

Report number

20170202-52652-2147407420

Ownership age

Not stated

Failure type

Fire / ignition

Incident narrative

SaferProducts.gov consumer incident report 20170202-52652-2147407420. Severity: Injury, First Aid Received by Non-Medical Professional. Product: Stihl MS460 (Chainsaw: Stihl MS460 with tool less fuel cap.). Incident: [REDACTED]. Temp was approx. 82-85 degrees, RH was approx. 28, and elevation was approx. 1200-1400 feet. The crew had just been ordered to the top of a ridgeline to help contain some spot fires that were produced from a run to the top of the ridgeline and spotted over holding line. One of the saw teams started up their saw (Stihl MS460) and noticed that the saw ran sluggish and was not wrapping out as usual. The sawyer stepped back from the fires black edge and opened the cap to visually inspect the fuel tank when a fuel geyser happened. The tank was 3/4 full of fuel. The sawyer was sprayed in fuel on his nomex shirt, gloves, and his face. The sawyer was wearing [REDACTED] goggles at the time this happened and suffered fuel to the eyes. The sawyer was treated with eye flushing by the crew EMT and a CA-1 was also filled out and filed with SMIS as precautionary measure. The Sawyer did not suffer any injury and there was no fire as result of the fuel geyser. The previous week the crew had noticed that a few of the 5 gallon fuel cans provided by the cache were labeled 2013. The fuel provided by the cache were also marked 40:1 mix ratio as well.

This is a consumer incident report published on SaferProducts.gov. CPSC does not guarantee the accuracy of information submitted by people outside of CPSC. It is not automatically an official recall or manufacturer admission.

Official report number: 20170202-52652-2147407420. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.