Verified government source

SaferProducts incident

Official U.S. Consumer Product Safety Commission consumer incident report from the SaferProducts.gov public database. Use the verification links below to confirm the record on SaferProducts.gov or via the public database export.

Product

LG LCS1112ST -01

Category

Kitchen Appliance

Report number

20170329-A3E09-2147404765

Ownership age

About 40 months to failure (from purchase date when reported)

Failure type

Fire / ignition

Incident narrative

SaferProducts.gov consumer incident report 20170329-A3E09-2147404765. Severity: Incident, No Injury. Product: LG LCS1112ST /01 (LG 1.1 Cu Ft MidSize Microwave StainlessSteel LG Model Number: LCS1112ST /01 Product Code: MS1142X.CS1EBBY Serial Number: 310TABN3M005). Incident: Last December my wife was using our LG Microwave oven when it began to emit acrid odor (burning smell). She turned off the unit and inspected the food product which was still cold. She started the microwave a second time and smelled the same odor. At this point she let the microwave rest for an hour and then attempted to heat something again only to smell the same order after a few seconds of operation. At this point she turned off and unplugged the microwave and left it for me to inspect. I'm a mechanical engineer and working in the field of forensics. Part of my job description also includes fire investigation. Upon inspection of the microwave I found evidence of a high resistance connection one of the microwaves thermal cutouts. The ABS base of the thermal cutout is melted and the crimp connection on ones side is welded on. Note, this connection was not welded at the time of manufacture, instead the welding happened as a result of the incident. LG Model Number: LCS1112ST /01 Product Code: MS1142X.CS1EBBY Serial Number: 310TABN3M005

This is a consumer incident report published on SaferProducts.gov. CPSC does not guarantee the accuracy of information submitted by people outside of CPSC. It is not automatically an official recall or manufacturer admission.

Official report number: 20170329-A3E09-2147404765. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.