Product
Bosch Dishwasher SHE3AR72UC-22
Category
Kitchen Appliance
Report number
20180125-C8463-2147393392
Ownership age
About 1 months to failure (from purchase date when reported)
Failure type
Fire / ignition
Incident narrative
SaferProducts.gov consumer incident report 20180125-C8463-2147393392. Severity: Incident, No Injury. Product: Bosch SHE3AR72UC/22 (White built-in dishwasher.). Incident: I purchased new Bosch dishwasher model SHE3AR72UC/22 from Best Buy this January of 2018. The wiring through my wall for the old one (which I also installed myself in the mid '80s) has only two wires (line and neutral). I decided to ignore the grounding warnings and connected the two wires to the screws on the machine that are plainly marked L and N. I noticed later that when I grabbed my stainless steel sink and touched the washer at the same time I was feeling a slight electric buzz so I decide that I should ground it just to be safe. I did not kill the breaker for this. I was surprised that when I touched the attached wire to ground there were sparks and I could be lightly shocked having skin between the ground and the end of the wire. Something's not right. After some consideration, I decided to switch the L and N wires so that they are connected to what should be the wrong screws as they are labeled. Now, even without the ground wire connected, there is no shock between the sink and machine, and there is also no sparking or juice at the ground when I do connect it. My point is that if a responsible person made all these connections with the power off before turning it on, he or she would not know that there was a constant feed of electricity flowing to ground which is a short but not enough to trip a breaker. I believe that many of the recalled dishwashers with overheating cords causing fires may have the same reversed connections that I found on this new machine which isn't even included in any recall yet. I cannot find anywhere that this is a known cause of these fire
Official report number: 20180125-C8463-2147393392. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.