Product
Masterbuilt 20072612
Category
Kitchen Appliance
Report number
20180319-C593C-1744920
Ownership age
About 45 months to failure (from purchase date when reported)
Failure type
Fire / ignition
Incident narrative
SaferProducts.gov consumer incident report 20180319-C593C-1744920. Severity: Injury, Level of care not known. Product: Masterbuilt 20072612 (40" electric smoker). Incident: 3/18/18 The caller plugged in the smoker to get ready for use. As he went to change the temperature, he touched the side of the smoker and said he received a small shock to his hand (No medical attention required). The caller continued to use the smoker. When he pulled out the chip tray he also got a tingling sensation like he was being shocked. The smoker was in use for about 1 hour and 30 minutes before it just shut off by itself. When the product shut off the caller removed the back plate to view the wires inside and noticed that the wires were corroded and could not maintain a good connection. The smoker was plugged into an extension cord with nothing else plugged into it. Caller believes this product it a shock and potential fire hazard. The caller contacted Masterbuilt They told him they were ware of the problem and he had to order a new burner kit.
Official report number: 20180319-C593C-1744920. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.