Product

Rheem Performance Platinum XG50T12HE40U0

Category

Home & Garden

Report number

20181029-88D8F-2147384747

Ownership age

About 1 months to failure (from purchase date when reported)

Failure type

Overheating

Incident narrative

SaferProducts.gov consumer incident report 20181029-88D8F-2147384747. Severity: Incident, No Injury. Product: Rheem Performance Platinum XG50T12HE40U0 (Gas Water Heater). Incident: I recently installed a Rheem gas water heater to as a replacement for an older heater. I attached the supplied draft vent hood to my existing 4 inch diameter flue. I performed the recommended draft test using a match and found sufficient draft for the operation of the appliance. After allowing the unit to operate overnight, I went to check the water connections for leaks. I observed that the plastic escutcheons and a plastic label on the top of the unit were melted. I contacted Rheem customer support and was instructed to perform the draft test again. Sufficient draft was present. While the Rheem supplied draft hood accepts a 4 inch flue, the opening for the flue gasses is 3 inches. It doesn't appear that this restricts the flow of the gasses, but does appear to reflect enough heat to melt the plastic components on the top of the unit. I've temporarily replaced the Rheem draft hood with one that has a true 4 inch opening and the melting condition has stopped. The CO detector in the basement hasn't activated, so I'm confident that the replacement draft hood is working properly.

This is a consumer incident report published on SaferProducts.gov. CPSC does not guarantee the accuracy of information submitted by people outside of CPSC. It is not automatically an official recall or manufacturer admission.

Official report number: 20181029-88D8F-2147384747. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.