Verified government source

SaferProducts incident

Official U.S. Consumer Product Safety Commission consumer incident report from the SaferProducts.gov public database. Use the verification links below to confirm the record on SaferProducts.gov or via the public database export.

Product

Kidde i12010S

Category

Smart Home Device

Report number

20181104-28F58-2147384654

Ownership age

About 57 months to failure (from purchase date when reported)

Failure type

Overheating

Incident narrative

SaferProducts.gov consumer incident report 20181104-28F58-2147384654. Severity: Incident, No Injury. Matched catalog product: Kidde i12010S. Source model text: Model i12010S. Incident: I have 5 of the Kidde Model i12010S combination smoke/CO detectors in my home and I have been having problems with them going off unprovoked. I started doing some research online and found this recall information and decided that I needed to let y'all know about the problems I experienced.

This is a consumer incident report published on SaferProducts.gov. CPSC does not guarantee the accuracy of information submitted by people outside of CPSC. It is not automatically an official recall or manufacturer admission.

Official report number: 20181104-28F58-2147384654. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.