Incident narrative
SaferProducts.gov consumer incident report 20190107-8038C-2147383380. Severity: Incident, No Injury. Product: Generac 20KVA propane fueled Power System Generac 20KVA Power Generator Model Number 0058750 (20KVA power Generator). Incident: Original Report Number Submitted 20190104-C782E-2147383419. This is to provide an update on the result of the explosion and fire. The problem resulted in the corrosion of a Fuel Plenum that is in the propane supply system. The fuel plenum became corroded and had a wall failure that allowed propane to leak into the unit enclosure and when the weekly maintenance run was initiated the propane was ignited and a explosion and fire occurred. Photos were previously submitted with the original report dated 1/4/2019
Official report number: 20190107-8038C-2147383380. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.