Verified government source

SaferProducts incident

Official U.S. Consumer Product Safety Commission consumer incident report from the SaferProducts.gov public database. Use the verification links below to confirm the record on SaferProducts.gov or via the public database export.

Product

Kidde i12010S

Category

Smart Home Device

Report number

20210621-C03CF-2147363392

Ownership age

About 81 months to failure (from purchase date when reported)

Failure type

Overheating

Incident narrative

SaferProducts.gov consumer incident report 20210621-C03CF-2147363392. Severity: Incident, No Injury. Matched catalog product: Kidde i12010S. Source model text: Ionization smoke alarm - I12010S. Incident: smoke detector failed in wee hours of the morning - after reset still went off - reported in email already and then noticed there is a recall on the exact ones i have - (6 in total)

This is a consumer incident report published on SaferProducts.gov. CPSC does not guarantee the accuracy of information submitted by people outside of CPSC. It is not automatically an official recall or manufacturer admission.

Official report number: 20210621-C03CF-2147363392. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.