SaferProducts incident

Official U.S. Consumer Product Safety Commission consumer incident report from the SaferProducts.gov public database. Use the verification links below to confirm the record on SaferProducts.gov or via the public database export.

Product

Trane Model: 4TTX8024A1000BA

Category

Home & Garden

Report number

20220701-EB100-2147355289

Ownership age

About 72 months to failure (from purchase date when reported)

Failure type

Stopped working / malfunction

Incident narrative

SaferProducts.gov consumer incident report 20220701-EB100-2147355289. Severity: Incident, No Injury. Product: Trane Model: 4TTX8024A1000BA (Central Air Conditioner). Incident: My Trane XL18i Central AC (installed 7/1/2016, see attached �Trane ID�) stopped working as of 5/17/2022. My 240V, 30A circuit breaker was tripped twice (once while the repairman was working on it) and a 5A fuse on the computer board (part of the furnace/AC control unit) burnt out multiple times as the repairman was working on the AC. The dealer repairman said mice have chewed up all the condenser wires, both inside the main condenser and in the electrical �box�. Close examination revealed two major flaws in the design of this unit: 1. Large Chassis Openings (see attached, �4x3 Opening�, and �3 Openings�): There is an opening, approximately 4�x3� in the chassis of the unit, for the refrigerant pipes. Above that are two round openings, approximately 1��, for wires. These openings are much too large to keep mice from access to critical electrical components. Other A/C brands ([REDACTED]) at my neighbors have much smaller openings, about �� clearance around the pipes. My neighbors did not have this problem with their A/C. 2. Wire Harness on Floor (see attachment, �Trane Wire Harness�): Inside the Trane condenser unit, the wire harness lies on the floor. The other major brands have their wire harness suspended about 8� above the floor. Even if a mouse got into the other units, it would be difficult for it to reach and chew on the suspended wires. It�s easy to see that these two factors together easily allowed mice to enter my Trane A/C unit and chewed up the wires. The Authorized Dealer�s technician replaced the wire harness, taped the 4�x3� opening with aluminum tape and caulke

This is a consumer incident report published on SaferProducts.gov. CPSC does not guarantee the accuracy of information submitted by people outside of CPSC. It is not automatically an official recall or manufacturer admission.

Official report number: 20220701-EB100-2147355289. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.