Verified government source

SaferProducts incident

Official U.S. Consumer Product Safety Commission consumer incident report from the SaferProducts.gov public database. Use the verification links below to confirm the record on SaferProducts.gov or via the public database export.

Product

York LY8S080A12UH11C

Category

Home & Garden

Report number

20231230-F315B-2147343125

Ownership age

Not stated

Failure type

Fire / ignition

Incident narrative

SaferProducts.gov consumer incident report 20231230-F315B-2147343125. Severity: Incident, No Injury. Product: York LY8S080A12UH11C (York LY8S080A12UH11C natural gas furnace). Incident: The pressure switch on my furnace failed, such that it would be stuck open circuit even when the draft inducer was running. However, the furnace still ignited and ran the burners for about a minute before shutting down. It did this a few more times before locking out. The furnace should not have ignited the burners at all in this case, because had the pressure switch been open because of a failure of the draft inducer or an obstruction in the exhaust pipe, it could have released combustion byproducts such as carbon monoxide into the living space. Additionally, as a troubleshooting step, I temporarily short-circuited the pressure switch, and I discovered that a pressure switch stuck closed does not cause a lockout. If I leave the furnace powered on and remove the short circuit, the furnace starts operation immediately. In this case, the furnace should have recognized a faulty pressure switch and locked out until reset. If instead the pressure switch had failed by being stuck closed, and then suddenly opened for some reason, the furnace could possibly operate with an unreliable pressure switch.

This is a consumer incident report published on SaferProducts.gov. CPSC does not guarantee the accuracy of information submitted by people outside of CPSC. It is not automatically an official recall or manufacturer admission.

Official report number: 20231230-F315B-2147343125. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.