Product
Ecowell ETH150
Category
Home & Garden
Report number
20240302-96E14-2147340639
Ownership age
About 5 months to failure (from purchase date when reported)
Failure type
Overheating
Incident narrative
SaferProducts.gov consumer incident report 20240302-96E14-2147340639. Matched catalog product: Ecowell ETH150. Incident: I was using an Ecowell ETH150 space heater on a bare concrete floor when I accidentally bumped it. I'd probably done this a few times before, but the final time I heard an electrical arcing noise and smelled burning plastic. I unplugged the heater. I was curious what had happened so I opened it to inspect it and found that the tip-over safety switch had completely melted and the leads had melted into the plastic plate the switch was mounted on.
Official report number: 20240302-96E14-2147340639. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.