Product

Elegoo Centauri Carbon

Category

Kitchen Appliance

Report number

20251011-CFF57-2147327162

Ownership age

About 4 months to failure (from purchase date when reported)

Failure type

Fire / ignition

Incident narrative

SaferProducts.gov consumer incident report 20251011-CFF57-2147327162. Severity: Incident, No Injury. Product: Elegoo Centauri Carbon (The printers are the Elegoo Centauri Carbon model, though the currently unreleased Elegoo Centauri may also be affected. The printers are grey boxes with steel panels on all sides and a smoke grey tempered glass top and front door. Printers are approximately 398 x 404 x 490 mm in overall size.). Incident: Elegoo Centauri Carbon 3D printers use a USB C cable which provides 24v power at up to 4.3A to the printhead PCB. Data lines are shielded twisted pair 24 AWG while power and gnd are untwisted 20 AWG. The strain relief on my printer's PCB failed exposing the wiring underneath and causing a short and toolhead board failure. Another user provided a video of a similar failure accompanied by visible and audible electrical arcing in the failed region of the cable, posing an immediate electrical fire hazard. The design of the printer's strain relief and cable chain puts it under stress during homing and printing operations that may contribute to failure. Community members have identified at least a dozen printers with some combination of strain relief deformation or separation from cable sheathing, bulging of cable sheathing, or visible helical twisting of insulated wires underneath the sheathing in the strained regions. Elegoo support provided a replacement cable to me but the recent report of visible electrical arcing, precedent of house fires andrecalls caused by strain relief failures in other 3D printers, and number of Centauri Carbon units with strain relief damage that went unnoticed until the problem was mentioned to them is concerning. My printer was preorder around 6/25/25, has an mfg. date of 6/04/25, and arrived around 8/10/25. I have included photos of my printer showing potential cable damage. Of the four units where total print time is know it ranged from 100-600 hours.

This is a consumer incident report published on SaferProducts.gov. CPSC does not guarantee the accuracy of information submitted by people outside of CPSC. It is not automatically an official recall or manufacturer admission.

Official report number: 20251011-CFF57-2147327162. Search that ID on SaferProducts.gov or match it in the CPSC public database export to verify this record.