Fire / ignition
Extension cord
[Translated from Japanese] NITE SAFE-Lite accident A201100084 (2011/02/08). Product: Ohm Electric HS-T2002W. Incident: After connecting an electric carpet to the product and turning it on, an abnormality was noticed after a while. Upon checking, it was found that a fire had occurred, causing burn damage to the product and the surrounding area. (accident location: Aichi Prefecture) Investigation note: The cause of the accident is considered to be that the crimped connection between the cord core wire and the blade receptacle bracket inside the power strip of the product was defective due to a disconnection, causing heat generation. Additionally, a kotatsu blanket was covering the power strip, leading to a rise in temperature inside the cord protector. This caused the insulation to melt, resulting in a short circuit and sparking in the cord core wire, ultimately leading to a fire. Cause class: n/a. Harm reported: 11.fire.
UnverifiedEvidence ★★★★☆View report detailsHide report details
Fire / ignition
Extension cord
Months until failure
Not stated
Repair cost
Not stated
Repaired
Not stated
Manufacturer warranty
Not stated
Extended warranty
Not stated
Support helpful
Not stated
Would recommend
Not stated
AI extraction confidence
86%
Verification status
Unverified
Evidence quality
★★★★☆ (4/5)