Fire / ignition
Air conditioner
[Translated from Japanese] NITE SAFE-Lite accident 2004-2452 (2005/02/11). Product: Daikin AR2205X. Incident: I requested an inspection because I heard a "crackling" sound from the outdoor unit of the air conditioner. During the inspection by the management company, they removed the top panel of the outdoor unit and looked into the electrical components, causing ignition and resulting in burns to the face. Investigation note: At the soldered connections between the printed circuit board and the diode bridge, there were instances of insufficient solder. Due to the difference in thermal expansion between the printed circuit board and the electrical equipment box, repeated stress was applied to the soldered joints, causing solder cracks. Consequently, reverse voltage was applied to the electrolytic capacitor, leading to damage to the capacitor itself and leakage of electrolyte. This resulted in sparking due to ignition, and it is presumed that the electrical equipment was burned or fire-damaged. Cause class: A2. Harm reported: 3. Minor injury. Reported use period: About 10 years.
UnverifiedEvidence ★★★★☆View report detailsHide report details
Fire / ignition
Air conditioner
Months until failure
Not stated
Repair cost
Not stated
Repaired
Not stated
Manufacturer warranty
Not stated
Extended warranty
Not stated
Support helpful
Not stated
Would recommend
Not stated
AI extraction confidence
86%
Verification status
Unverified
Evidence quality
★★★★☆ (4/5)