Fire / ignition
Ventilation fan (ceiling-recessed type) [Ventilation fan]
[Translated from Japanese] NITE SAFE-Lite accident 2006-0968 (2006/07/19). Product: Mitsubishi VL-1600Z-1. Incident: I heard a "crackling" sound from the ventilation fan, so I opened the panel to check, and smoke emission ignited. Investigation note: This is a ventilation fan that simultaneously intakes and exhausts air. It was used for a long period (approximately 16 years) in an environment where it exhausted indoor air during cooling and intook hot and humid outside air. It is presumed that hot and humid outside air entered and condensed near the terminal block inside the equipment, causing insulation breakdown at the power supply terminal, leading to tracking, smoke emission, and ignition. Cause class: C1. Harm reported: 4. Property damage (extended). Reported use period: Around April 2016.
UnverifiedEvidence ★★★★☆View report detailsHide report details
Fire / ignition
Ventilation fan (ceiling-recessed type) [Ventilation fan]
Months until failure
Not stated
Repair cost
Not stated
Repaired
Not stated
Manufacturer warranty
Not stated
Extended warranty
Not stated
Support helpful
Not stated
Would recommend
Not stated
AI extraction confidence
86%
Verification status
Unverified
Evidence quality
★★★★☆ (4/5)