Product image pending

We track images separately from defect reports.

Home & Garden

Goodman Model Desc: 1824 HORIZONTAL BUTT UP

2 source-linked failure reports. Most reported: Fire / ignition. Typical failure around 4.1 yr.

Reliability signal — · Insufficient data · data confidence Very Low

2 confirmed failure reports

Reliability summary

What is likely to go wrong, when it happens, and how expensive it can be — from source-linked failure reports. Counts are reports in our database, not a population failure rate.

Reliability signal

—

2 confirmed failure reports · Insufficient data · Data confidence: Very Low

Need at least 5 confirmed failure-signal reports before showing an A–F grade.

Most common issue
Fire / ignition
Typical first failure
4.1 yr
Median of confirmed reports with timing
Median repair cost
—
Reported costs only · market varies
Highest reported repair
—
Not a quote · costs differ by country

What breaks?

Failure types

Click a type in the reports section below to filter.

  • Fire / ignition2 · 100%

When does it break?

Failure timing

Months after purchase, using reports that included timing.

What does it cost?

Reported repair costs

Distribution of owner-reported repair costs— not a quote or guarantee. Labor and parts prices vary by country.

No reported repair costs yet for this model.

Median months to failure

49.5

Failure reports

2

View →

Median repair cost

—

Still recommend

—

% repaired

—

% mfr warranty

—

% extended warranty

—

% support helpful

—

Use these reports as a risk signal, then check current listings before you buy.

Search this model on Amazon

As an Amazon Associate, After Warranty may earn from qualifying purchases.

What breaks?

What breaks? · reports

Fire / ignition

Furnaces, Other or Not Specified (322)

51 months

Government / agencyIndexed Oct 28, 2026Source-linkedVerify source — SaferProducts.gov incident

SaferProducts.gov consumer incident report 20231103-E395A-2147344220. Matched catalog product: Goodman Model Desc: 1824 HORIZONTAL BUTT UP. Source model text: CAPF1824A6. Incident: Goodman Furnace coil caught on fire in my furnace, Fire and smoke damage to the furnace, insulation, ducts and my home. I have reach out to Goodman at the number listed 888-520-0579 and they have not helped at all. This unit was purchased on 8/4/2019 and is under warranty until 8/4/2029 this is the email [REDACTED] address of the Goodman employee that took my information.

UnverifiedEvidence ★★★★☆
View report details

Months until failure

51 months

Repair cost

Not stated

Repaired

Not stated

Manufacturer warranty

Not stated

Extended warranty

Not stated

Support helpful

Not stated

Would recommend

Not stated

AI extraction confidence

92%

Verification status

Unverified

Evidence quality

★★★★☆ (4/5)

Discussion

Fire / ignition

Heaters or Heating Systems, Other or Not Specified (393)

48 months

Government / agencyIndexed Oct 16, 2026Source-linkedVerify source — SaferProducts.gov incident

SaferProducts.gov consumer incident report 20230102-F3892-2147351708. Severity: No Incident, No Injury. Product: Goodman Model Desc: 1824 HORIZONTAL BUTT UP (HVAC unit / AC and heat). Incident: This is regarding a Goodman split HVAC unit that caught on fire, which was only resolved by turning off the circuit breaker to the unit. Details of product: Goodman Model: CHPF1824A6 Model Desc: 1824 HORIZONTAL BUTT UP Manufacture Date: 12/01/2017 Serial Number: 1711577748 For two years, we have two of these units in my home. On 12/30 overnight, one unit ran overnight at full power and would not shut off, even when I turned off the [REDACTED] thermostat (which was set to 72-73, and the temp detected was 82). It turned off when I flipped the circuit breaker, however the circuit breaker would not turn back on. HVAC repairperson came same day and smelled that there was a fire inside the HVAC unit furnace. It melted a pipe, some wires, and also melted the safety sticker on the inside of the cover. Thankfully we were at home to shut it off. My electrician wrote, "no safety mechanism worked or worked at the very critical point. There are at least 2-3 heat cut/kill switches on Board which really maxed out before that burning occurred. Terrible terrible. Critical infra failure of the worst kind and kind and yet something at a very last point functioned and blocked the whole thing, you turned off the breaker."

UnverifiedEvidence ★★★★☆
View report details

Months until failure

48 months

Repair cost

Not stated

Repaired

Not stated

Manufacturer warranty

Not stated

Extended warranty

Not stated

Support helpful

Not stated

Would recommend

Not stated

AI extraction confidence

88%

Verification status

Unverified

Evidence quality

★★★★☆ (4/5)

Discussion

Compare nearby models

Similar products

Stay ahead of failures

Notify me about this model

Get an email when a new source-linked failure report is published for the Goodman Model Desc: 1824 HORIZONTAL BUTT UP.

We only email when a new published report is added for Goodman Model Desc: 1824 HORIZONTAL BUTT UP. No spam, unsubscribe by contacting support.

Contribute signal

Had a failure with this model?

Add your experience and help future shoppers understand what happens after the warranty.

Submit your experience